Panel mount digital tension indicator (1/8 Din Cutout) with analog output and user-set MIN and MAX alarm limits. Can be used with all 3-roller tension sensors TE, TF, TSW, TS2, and other sensors that provide an analog output signal 0 - 1V DC.
Storage for 4 different material calibrations (standard + 3 customer-supplied materials)
Output
– analog (standard): 0 – 10 V DC
– digital (standard): USB and RS-422
– digital (optional): CAN-Bus (on request)
– current (optional): 4 – 20 mA (instead of 0 – 10 V DC)
Rear Panel of Indicator: Terminal strip for Hi/Lo Alarms, Sensors Input, RS-422 output & 24V Power Input.
USB Output is on the front of the display.
– analog (standard): 0 – 10 V DC
– digital (standard): USB and RS-422
– digital (optional): CAN-Bus (on request)
– current (optional): 4 – 20 mA (instead of 0 – 10 V DC)
Rear Panel of Indicator: Terminal strip for Hi/Lo Alarms, Sensors Input, RS-422 output & 24V Power Input.
USB Output is on the front of the display.
- Connection of series TE, TF, TSW, TS2 and other with analog output 0 - 1 V DC, optionally series without integrated amplifier
- User set limits (Min and Max alarms) with Visual Indicator with Open Collector output
- Adjustable damping to reduce tension fluctuates
- Panel mounted digital display
- 3 different display modes – numeric – numeric with live bargraph – numeric with graph (time v tension)
- Storage for 4 different material calibrations (standard + 3 customer supplied materials)
- CE certified
- Scale to desired engineering units of cN, N, daN, g, kg and lb
- Operates from 15-24V DC power. 100-240V AC
- AC-to-DC Wall Plug Adapter optionally available (p/n AC-SC-PM)
Name | Output Signal |
---|---|
Standard |
analog 0 - 10 V DC open collector |
Code A3 |
4 - 20 mA instead of 0 - 10 V DC open collector |
Code 232 |
digital RS-232 analog 0 - 10 V DC open collector Up to 100 readings can be transfered per second |
Code 422 |
digital RS-422 analog 0 - 10 V DC open collector Up to 100 readings can be transfered per second |
Click picture for more information |
Digital display | Colored TFT 128 x 160, backlit |
Measuring Units | cN, daN, lbs, g or kg selectable depending on range |
Calibration | Storage for 4 different materials (standard adjustment + 3 customer supplied materials) |
Selectable Damping | 9 adjustable settings (electronic damping, moving averaging) |
Output signal | Analog: 0 – 10 V DC /R (Last) ≥ 5kΩ, update time 1 ms (1000 Hz) Digital: USB (1 kHz) and RS-422 (200 Hz) Current (option): 4 – 20 mA instead of 0 – 10 V DC |
Input signal | 0 - 1 V DC, option mV |
Alarm limits | Programmable MIN/MAX limits with LED |
Alarm output | Open Collector max. 30 V DC, 10 mA |
Power Required | SC-PM: 15 - 24 V DC, 100 mA (Regulated) AC-SC-PM: 100-240V AC, using optional AC/DC Adapter (plugs into AC wall outlet) |
Temperature range | 10 - 45° C |
Air humidity | 85 % RH, max. |
Housing | Plastics |
Dimensions | 115 x 95 x 48 mm (LxWxH), mounting cut out 92 x 44 mm |
Weight, net (gross) | Approx. 200 g (Approx. 300 g) |