View Larger Image
|
|
TI-1071 Intrinsically Safe Ultrasonic Wall Thickness Gauge | Measuring Range in Steel
TI-1071: 0.048 - 10.00 inches (1.2 - 250.0 mm)
TI-1071-TW: 0.030 - 1.000 inches (0.7 - 25.0 mm)
TI-1071-HW: 0.160 - 16.00 inches (5.0 - 400.0 mm)
The new CHECK-LINE TI-1071 Intrinsically Safe Ultrasonic Wall Thickness Gauge accurately measures wall thickness and the extent of corrosion of all metals, ceramics, glass and most rigid plastics - from only one side! |

Limit value guides and monitoring | Adjustable sensitivity | Includes protective vinyl pouch with clear plastic window for safe use in rugged environments. |
| Energy saving mode | Accuracy ± 0.0019" (0.05 mm) | Class I Zone 0 AEx ia IIC T4
I.S. Class I Divison 1 Group A-D T4 |
|

| | | NIST-Traceable Steel Test Block 3 Sizes Available |  | Precision Machined and Finished
Includes NIST-Traceable Report and Test Data
| | | Click image for more info
| ___________________________________________ |
| | | Uncertified Steel Test Block For Ultrasonic Gauges |  | For convenient confirmation of thickness gauge calibration
| | | Click image for more info
| ___________________________________________ |
| | | CF12 Coupling Fluid |  | Used to create an ultrasonic coupling between the probe and material to be measured
12oz Bottle
| | | Click image for more info
|
|

| | | | The TI-1071 is supplied as a complete kit including the Gauge, transducer, protective pouch, coupling fluid and instruction manual all in a foam fitted carrying case. |
 |

|
Uncertified Steel Test Block For Ultrasonic Gauges |  |
For convenient confirmation of thickness gauge calibration
| | Click image for more info
|

| Ex designation: |
II 2 (1) G EEx ia IIC T4 |
| EC-Certificate of Conformity: |
PTB 97 ATEX 2231 X |
| fm-approved: |
Class I Zone 0 AEx ia IIC T4 I.S. Class I Divison 1 Group A-D T4 |
| Ingress protection: |
IP 54 |
| Accuracy |
± 0.0019" (0.05 mm) |
| Dimensions: |
120 x 65 x 25 mm |
| Weight: |
150 g |
| Operating temperature: |
-10 °C to 50 °C |
| Storage temperature: |
-20°C to 60°C (without batteries) |
| Supply: |
2 x primary cells AA to IEC LR6 |
| Working time: |
200 hours continuous operation 1-2 years stand-by |
| Instrument: |
operation permitted in zone 1 |
| Probes: |
operation permitted in zone O can be exchanged in hazardous areas standard sensor operating temperature up to 200°C for a short time |
| Couplant: |
perfect connection between sensor and material |
| Vulcollan film: |
prevents wear of probe if it is used on rough surfaces |
|


|